- 150g bag
- Recommended filling density; 130g/dm2
- Each silencer requires stainless wire wool to wrap around the perforated tubing AND E-Glass wool to act as sound damping. See below in conjunction with the wool data table:
For calculation of wool required to fill a silencer use the following process:
- Calculate the casing end plate area (a) in dm2.
- Calculate the area of the perforated tubing (b) in dm2.
- Subtract (b) from (a) which equals the usable face area of the silencer (c) in dm2.
- Multiply (c) by the length of the silencer (L) which is the volume of the silencer (v).
- Multiply the volume (v) by the number of recommended grams per dm2 (130).
- This weight (w) in grams is then divided by 150 to identify how many bags of E-Glass wool are required.
Example:
Casing = 140/220mm
L = 350mm
Perforated tube = 63.5mm
Recommended wool density = 130g/dm2
Wool in g = (((Casing area – Tubing area) x L) x 130) / 150
(((2.334-0.317) x 3.5) x 130) / 150
Answer = 918g or 6 bags
Weight | 0.150 kg |
---|---|
Material | E-Glass Wool |
Part Number | U4G150A |